Mauro Ferrero, TRIGENIA S.r.l., Italy Dario Agnese, Trigenia, Italy Armando Portoraro, Trigenia, Italy Michele D'Aleo, SKF Industries, Italy Gennaro Sinisi, SKF Industries, Italy

Abstract

Industrial organizations are setting challenging decarbonization goals in response to European CO2 emission reduction commitment and growing awareness of ESG factors. Special efforts are required for thermal needs (Scope 1, according to the "Greenhouse Gas Protocol") and electrical needs (Scope 2).

While the reduction of CO2 emissions attributed to Scope 2 is achievable through a) energy efficiency, b) use of on-site Renewable Energy Sources (RES) and c) purchase of Renewable Energy Guarantees of Origin (REGO) or RES Power Purchase Agreement (PPA), the reduction of emissions related to thermal needs is more challenging due to greater technological complexity, higher investment costs, and the current absence of REGO for fuels.

To address this need, the use of electric Heat Pumps (HPs), capable of raising the enthalpy level of a low-temperature source (renewable or waste heat), may efficiently shift thermal needs to Scope 2, allowing the use of REGOs to offset the related emissions.

SKF Industries, world leader in the mechanical sector, aims to improve energy efficiency and reduce natural gas consumption in the production sites, according to the Group decarbonization policy within 2030 and 2050.

Trigenia, an Italian Energy Service Company, applied the abovementioned approach to the Villar Perosa (TO) production plant, where a high contemporaneity of heating and cooling needs allows a thermal recovery with a flexible configuration of heat pumps.

The intervention, completed in January ‘25, is based on the reduction of thermal and cooling needs through the implementation of a predictive plant management system and the optimization of hot and cold water production. After these energy measures, a set of heat pump has been designed and installed: a) an air/water HP, working as a chiller (Evaporator -eva- : 7-12°C) in summer and a low temperature HP in winter (Condenser -cond- : 25-30°C); b) a water/water HP working as a total recovery chiller in summer (eva: 7-12°C, cond: 50-60°C) and as a booster in winter (eva: 25-30°C, cond: 60-70°C), using HP a) as hot well.

As a result, the system 1) reduces overall natural gas consumption, that is Scope 1 emissions, by 85%; 2) ensures high annual COP value, lowering energy costs; 3) optimizes the investment costs (same HPs for cooling and heating); and 4) obtains Tradable White Certificates, for a significant improvement in the economic performance of the project.