Abstract
Smart heating and battery technologies are beginning to be deployed in UK homes to alter the timing of domestic energy demand to enable residential demand side response (DSR). This paper empirically evaluates the impact of DSR trials on grid electricity import and household experience regarding disruption to routines, thermal comfort and noise disturbance in 17 thermally efficient social housing dwellings (Barnsley, England) with air source heat pumps, 5 kWh smart batteries and solar photovoltaic panels (1.3–3.0 kWp). Four DSR trials were run during the latter part of the heating season of 2021 to shift electricity demand away from peak times using automated control of battery and heat pumps to impose two-hour ‘turn-down’ interventions during peak times and two-hour ‘turn-up’ interventions at expected times of local surplus renewable generation. The turn-down trials were driven by price signals (time of use tariffs) and grid carbon intensity. While during turn-down interventions grid electricity import was minimised, it was increased through battery charging and heat pump use during turn-up trials. Internet of Things based sensors recorded time-series data on grid electricity use, battery charging-discharging and heat pump electricity use. Telephone surveys were conducted with residents following the trials.
All turn-down interventions reduced grid import electricity. or time of use trials, grid import was reduced up to 1.7 kWh per household (85 %) between 5–7 pm and controllable load was reduced up to 4.3 kWh per household. For the turn-up trials, grid electricity import was increased up to 3.6 kWh per household and controllable load was increased up to 2.6 kWh per household between 1–3 pm. Household surveys revealed general concerns about the project related to fuel costs, indoor temperature and hot water temperature. Although a few households noticed battery noise during the trials, no one reported it as a concern. For 77 % of responses, trial changes were acceptable even amongst households who noticed changes in indoor temperature and battery noise. The general acceptability of automated DSR, under thermal comfort limits and manual override, are promising for the wider application of domestic DSR driven by price signals, although a continued focus on individual user support regarding the deployment of new technologies is needed. Additionally, individual dwellings may show different levels of demand response depending on the levels and patterns of electricity consumption.
Downloads
Download this paper as pdf: 5-273-22_Gupta.pdf
Panels of
1. Dynamics of consumption: less is more?
2. Efficiency and beyond: innovative energy demand policies
3. Policy, finance and governance
4. Monitoring and evaluation for a wise, just and inclusive transition
5. Towards sustainable and resilient communities
6. Energy-efficient and low-carbon mobility for all
7. Policies and programmes for better buildings
8. Innovations in products, systems and building technologies