Search eceee proceedings

Embodied and operational carbon of construction products: an evaluation of the impact of using double or triple glazed windows with coatings in the EU

Panel: 8. Products, systems and technologies to decarbonise buildings

This is a peer-reviewed paper.

Author:
Justin Loup, Glass for Europe, Belgium

Abstract

To reduce overall CO2eq emissions in the EU, one route pursued by authorities is to move towards zero-emission buildings. The emissions from heating/cooling a building (operational CO2) and the emissions during its construction (embodied CO2eq) thus need to be minimised. This entails evaluating which construction products minimise whole-life carbon emissions (WLC) considering both factors. In this contribution, high-performance windows are taken as a case study.

Relying on preexisting models, the embodied and operational carbon impacts of various windows on a residential building model in different EU climates are calculated. This shows that using low-e coated triple glazed windows in the studied buildings generally results in the least CO2eq impact. The performance of these windows permits CO2 savings during the operational phase of the buildings that are high enough to compensate for the incremental CO2eq emitted for their production when compared to low-e double glazed windows. In Southern EU countries, for the studied models, solar control triple glazed windows generate fewer embodied and operational carbon than low-e double or triple glazed windows.

These conclusions cannot be used to choose windows for a given building project but they provide general information on windows’ WLC in Europe. After displaying the methodology and findings, the paper presents a calculation tool developed to obtain results with bespoke parameters and enable a more thorough evaluation of window-related carbon emissions in Europe.

Errata

Tables 2, 3 and 5 have been corrected and the adjoining text has been changed accordingly. (2024-09-05)

Downloads

Download this display as pdf: 8-069-24_Loup_display.pdf

Download this paper as pdf: 8-069-24_Loup_rev.pdf