Evaluating non-domestic building stock simulation based on single-zone models with multi-zone average usage profiles
Panel: 8. Products, systems and technologies to decarbonise buildings
This is a peer-reviewed paper.
Authors:
Christian Karczewski, Germany
Julian Bischof, Institute for Housing and Environment, Research Institution of the State of Hesse and the City of Darmstadt, Germany
Michael Hörner, n/a, Germany
Abstract
Building stock models are valuable tools for the determination of building stock-related efficiency impacts on greenhouse gas reduction strategies. The building stock is often simulated based on building models with a single usage zone to cope with missing information and computational expenses. Especially in the case of non-domestic building types that combine very different uses under one roof, such as production buildings for instance, the attribution of a single standardized usage profile can lead to considerable uncertainties in the calculation of energy demands.
The aim of this work is twofold. The first goal is to determine average usage profiles that are specific to non-domestic building categories and their typical zoning. The second goal is to evaluate these profiles’ capability to reduce uncertainties in single-zone models.
In recent work, the floor area shares of typical usage zones for non-domestic building categories in Germany were determined. In this work, these building categories are matched to the building categories of the German non-domestic building research database. Averaged profiles with weighted parameters are determined for these building categories by combining the typical floor area shares with the standardized DIN V 18599 usage profiles. Next, demand benchmarks for heating, cooling and lighting are calculated based on a multi-zone building model (M), considering the typical zoning in each building type. These demands are compared to the results of single-zone building models with one predominant usage (S) as well as to the results of single-zone building models with averaged usage profiles (S+).
The comparison shows that the S+ results closely align with the M results, while the S results show significant deviation. Consequently, the averaged usage profiles provide a simple way of reducing the usage-based uncertainties for single-zone building stock models. The developed building category-specific usage profiles are publicly available on GitHub.
Downloads
Download this paper as pdf: 8-068-24_Karczewski.pdf
Download this presentation as pdf: 8-068-24_Karczewski_pres.pdf